Overview
Physioled Sonora Cryo SNR005 combines ultrasound and cooling through a dedicated handpiece. It is a distinct configuration from standard Sonora and Sonora Combi. It is not a cooling system with wraps and does not include the Combi version's electrotherapy function.
Ultrasound emission can be continuous or pulsed, with programmable intensity and duration. The range offers preset and custom programs and recognition of the connected accessory. Current and voltage values in the table apply only to Combi, not standard Sonora or Cryo.
Model comparison
| Model | Sonora | Sonora Combi | Sonora Cryo |
|---|
| Manufacturer code | SNR001 | SNR003 | SNR005 |
| Ultrasound frequency | 1–3 MHz | 1–3 MHz | 1–3 MHz |
| Maximum intensity | 3 W/cm² | 3 W/cm² | 3 W/cm² |
| Electrotherapy | No | Yes | No |
| Cryotherapy | No | No | Yes |
| Electrical input power | 70 VA | 100 VA | 300 VA |
| Maximum direct current | — | 30 mA | — |
| Maximum pulse current | — | 70 mA | — |
| Maximum output voltage | — | 100 Vdc | — |
Technical data
| Technical data | Physioled Sonora Cryo – cryo-ultrasound therapy unit |
|---|
| SKU | FITLED001 |
| Manufacturer code | SNR005 |
| Ultrasound frequency | 1–3 MHz |
| Maximum intensity | 3 W/cm² |
| Emission mode | Continuous / pulsed |
| Power supply | 90–240 Vac / 50–60 Hz |
| Electrical input power | 300 VA |
Included equipment
| Accessory | Code | Quantity |
|---|
| Power cable, 2 m | 00100.03 | 1 |
| Ultrasound and cryotherapy handpiece Ø 65 mm | SNRMC1 / SNRMCR01 | 1 |
One 65 mm US + Cryo handpiece is included. Documentation identifies it as SNRMC1 / SNRMCR01; confirm the replacement part code before ordering. Check the operating temperature and use conditions in the supplied configuration's manual.
Accessories on request
Optional accessories are quoted separately on request using the unit and accessory codes. Items included in the configuration need not be purchased again; they may be ordered separately as replacements. Compatibility and delivery time are confirmed in the quotation.
| Accessory | Code |
|---|
| Handpiece holder | SNRPM01 |
| Handpiece holder | PANTOGRAFO + ARSNRSUP01 |
Use and safety
For professional use by trained personnel following patient assessment and the contraindications in the model's manual. Select settings, position the handpiece or electrodes and clean the equipment according to the manufacturer's instructions. Do not assume the Cryo handpiece can be submerged or that accessories are interchangeable between models. This page does not replace the manual or prescribe an individual treatment protocol.
Frequently asked questions
How do I choose the model?
Physioled Sonora Cryo SNR005 combines ultrasound and cooling through a dedicated handpiece. It is a distinct configuration from standard Sonora and Sonora Combi. It is not a cooling system with wraps and does not include the Combi version's electrotherapy function.
Which accessories can I order separately?
Optional accessories are quoted separately on request using the unit and accessory codes. Items included in the configuration need not be purchased again; they may be ordered separately as replacements. Compatibility and delivery time are confirmed in the quotation.
What should be checked before use?
For professional use by trained personnel following patient assessment and the contraindications in the model's manual.
Physioled Sonora / Combi – ultrasound therapy unit · Ultrasound · Cryotherapy